The fact that it took 2 days to get service was disappointing after the first tech said he couldn't find the ac unit on the roof.
Robert provided very professional service. His explanation of what was done and documentation in the email were accurate and complete.
Always honest, on time, professional, and friendly. They do great work, we've had them install 2 new ACs and a water heater in our family homes.
Lance was very professional, respectful and thorough!!
Noise coming through drain line from another condo.system cooling well at this time.
Performed system maintenance. Unit is installed in condo. Could not access supply ducts as they are in ceiling and unit has no return duct. All electrical and mechanical components are functioning properly. Homeowner will be in PA. They will call to schedule next maintenance.
Remove grilles and rotobrush duct clean each supply was not done because the ductwork wasductbored. Chris and Caleb replaired ductleaks for 89$
Could not access ducts as they are under the floor of the condo bldg. did not clear drain line as it is linked into one common line and I do not want to damage it. Put approximately 4oz of drain solv with 4oz of water down condensate line to help make sure it is clean. Compressor amps are good, cond fan amps are good. Caps are good for air handler and condenser.
PTU: total precision tune-up, Remove debris from outdoor unit, wash out condenser coil, light brush and inspection of evaporator coil, check microfarad values of all capacitors, check contact points on starter, check amp draw of both motors, lubricate where applicable, monitor refrigerant pressures, & thoroughly blow out drain line.
sold 14 seer rheem over the water heater a/c system with solice.install Saturday financed with greensky 12 sac.compressor has open windings and wires melted in unit.
Qouted 1.5 ton 19 seer mini split.also need to run larger wire from panel to mini split.other company did not realize cir it that was ran when sunroom was built is only a#12 Romex and is 60' in length and is to small.
Delivered air cleaner media to homeowner and stopped the rattling and squeaking of the condenser.
Homeowner is very interested in a solace Air cleaner but after talking to her about this, I realized the unit was not cooling properly. Unit is not moving heat, checked amp draw on compressor and there was none, capacitor was weak so I changed it temporarily to rule that out as a problem and it still didn't work. 1.3 ohms when checking windings on the compressor. Compressor is bad so I went over options with homeowner and set follow up for replacing unit along with IAQ package
System not cooling. Found indoor fan motor module inoperable. Need to order motor module and schedule install.
No cool, system is 12 yrs old and has shorted condenser wire and contactor is burnt and pitted. Compressor is loud and has not been serviced. Customer can not afford system replacement and said she will call in a month or so when she can afford maintenance and contactor
System not cooling. Found indoor fan motor module inoperable. Need to order motor module and schedule install.